Gocator Line Profile Sensors: User Manual
Getting Started • 34
To terminate the cordset's shield:
1. Expose the cordset's braided shield by cutting
the plastic jacket before the point where the
cordset splits.
2. Install a 360-degree ground clamp.
Master Network Controllers
The rack mount brackets provided with all Masters are designed to provide adequate grounding through
the use of star washers. Always check grounding with a multi-meter by ensuring electrical continuity
between the mounting frame and RJ45 connectors on the front.
When using the rack mount brackets, you must connect the frame or electrical cabinet to which
the Master is mounted to earth ground.
You must check electrical continuity between the mounting frame and RJ45 connectors on the
front using a multi-meter.
If you are mounting Master 810 or 2410 using the provided DIN rail mount adapters, you must ground
the Master directly; for more information, see Grounding When Using a DIN Rail (Master 810/2410) on the
next page.