Gocator Line Profile Sensors: User Manual
Protocols • 476
Clear Replay Data
The Clear Replay Data command clears the sensors replay data..
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4513).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4513).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Get Playback Source
The Get Playback Source command gets the data source for data playback.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4524).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4524).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
source 32s 10 Source
0 – Live
1 – Replay buffer
Reply
Set Playback Source
The Set Playback Source command sets the data source for data playback.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4523).
source 32s 6 Source
0 – Live
1 – Replay buffer
Command

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 800 and is the answer not in the manual?

LMI Technologies Master 800 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 800
CategoryAccessories
LanguageEnglish

Related product manuals