Gocator Line Profile Sensors: User Manual
Protocols • 469
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4539).
Voltage k16u 10 0: 48 Volts; 1: 24 Volts.
Cable Length k16u 12 0 – 100: Meters
Reply
Set Voltage Settings
The Set Voltage Settings command sets the sensor’s voltage and cable length settings.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4538).
Voltage k16u 6 0: 48 Volts; 1: 24 Volts.
Cable Length k16u 8 0 – 100: Meters
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4538).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Get Quick Edit Enabled
The Get Quick Edit Enabled command returns whether Quick Edit mode is enabled on the sensor.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4541).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4541).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Enable 8u 10 0: disabled; 1: enabled.
Reply
Set Quick Edit Enabled
The Set Quick Edit Enabled command enables or disables Quick Edit mode on the sensor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 800 and is the answer not in the manual?

LMI Technologies Master 800 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 800
CategoryAccessories
LanguageEnglish

Related product manuals