Field Type Offset Description
resetIp 8u 6 Specifies whether IPaddress should be restored to default:
0 – Do not reset IP
1 – Reset IP
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4301).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Get Recording Enabled
The Get Recording Enabled command retrieves whether recording is enabled.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4517).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4517).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
enable 8u 10 0: disabled; 1: enabled.
Reply
Set Recording Enabled
The Set Recording Enabled command enables recording for replay later.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4516).
enable 8u 6 0: disabled; 1: enabled.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4516).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 800 and is the answer not in the manual?

LMI Technologies Master 800 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 800
CategoryAccessories
LanguageEnglish

Related product manuals