Gocator Web Interface • 330
Name Description
Memory Usage Sensor memory utilization (MB used / MB total available).
Storage Usage Sensor flash storage utilization (MB used / MB total available).
Ethernet Link Speed Speed of the Ethernet link (Mbps).
Ethernet Traffic Network output utilization (MB/sec).
Internal Temperature Internal sensor temperature.
Processing Latency Last delay from camera exposure to when results can be scheduled to.
Processing Latency Peak Peak latency delay from camera exposure to when results can be scheduled to rich
I/O. Reset on start.
Alignment State
Whether the sensor or sensor system has been aligned.
Over Temperature State
Whether the internal temperature of the sensor is over a predetermined level.
Over Temperature Duration
The amount of time that the internal temperature of the sensor has been over a
predetermined level. (Some models only.)
Name Description
Scan Count* Number of scans performed since sensor state last changed to Running.
Trigger Drop** Count of camera frames dropped due to excessive trigger speed.
Processing Drop** Count of frame drops due to excessive CPU utilization.
Ethernet Output Drop** Count of frame drops due to slow Ethernet link.
Analog Output Drop** Count of analog output drops because last output has not been completed.
Serial Output Drop** Count of serial output drops because last output has not been completed.
Digital Output 1 Drop** Count of digital output drops because last output has not been completed.
Digital Output 2 Drop** Count of digital output drops because last output has not been completed.
Digital Output 1 High Count Count of high states on digital output.
Digital Output 2 High Count Count of high states on digital output.
Digital Output 1 Low Count Count of low states on digital output.
Digital Output 2 Low Count Count of low states on digital output.
Anchor Invalid Count** Count of invalid anchors.
Valid Spot Count Count of valid spots detected in the last frame.
Max Spot Count*
Maximum number of spots detected since sensor was started.
Camera Search Count Count of camera frame where laser has lost tracked. Only applicable when tracking
window is enabled.
Dashboard History Values
*When the sensor is accelerated, the indicator's value is reported from the accelerating PC.
** When the sensor is accelerated, the indicator's value is the sum of the values reported from the
sensor and the accelerating PC.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Master 800 and is the answer not in the manual?

LMI Technologies Master 800 Specifications

General IconGeneral
BrandLMI Technologies
ModelMaster 800
CategoryAccessories
LanguageEnglish

Related product manuals