8-22
Issue 9 October 1998
363-206-204
Releases 9 and 11 Installation Tests
4. Disconnect the receive or ‘IN’ fiber of the OLIU receiving traffic (as deter-
mined by the previous step).
5. Enter the command
rtrv-state-path;.
6. Verify that all traffic has switched from the OLIU with the disconnected fiber
to the OLIU that is still connected.
7. Reconnect the receive or ‘IN’ fiber.
8. Verify that alarms clear. If alarms do not clear refer to the ‘Troubleshooting’
Section of this manual. Continue with the next shelf.
Final Operations
Procedure
1. Verify that all test signals and loopbacks from the DDM-2000 OC-3 have
been removed.
2. Press the UPD pushbutton on the SYSCTL.
3. Verify that the system is configured for normal operation and that no alarms
are present
4. If alarms are present, refer to the "Troubleshooting" section of this manual.
5. Connect the office alarm cables if they have been disconnected.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals