363-206-204
Operational Tests
Issue 9 October 1998
10-19
Notes
:
1. Inputs to the minor alarm and power minor alarm connections are normally derived from
the -48 volt alarm outputs of a
SLC
® Series 5 Carrier System power shelf. 9 external
ground must be connected to output-common to access the alarm. Refer to Figure 9-1
(Releases 6 and 7) or Figure 9-3 (Releases 8, 9, 11 and 13).
2. The external inputs to the miscellaneous (environmental) discretes is a contact closure
and is connected to the DDM-2000 by two leads (wires). For each of the miscellaneous
(environmental) inputs that are being used, connect one lead to input-common (TLMI-C)
and the other lead to the appropriate alarm designation (TLMI-#). Refer to Figure 9-1
(Releases 6 and 7) or Figure 9-3 (Releases 8, 9, 11 and 13).
Table 10-2. Miscellaneous (Environmental) Discrete Telemetry Connections (RT)
Remote Terminal (All Releases)
Remote Terminal
Additional Environmental Inputs
(Releases 8, 9, 11 and 13 only)
Name Desig. Conn. Name Desig. Conn. Term Color
Minor Alarm
Power Minor Alarm
Fan Control
Input-Common
MN
PMNT-IN
FAN-CTL
TLMI-C
J62 Env. Input - #17
Input-Common
TLMI-17
TLMI-C
J61 4
18
23
9
W-O
R-BR
O-BK
S-W
Env. Input - #1
Env. Input - #2
Env. Input - #3
Env. Input - #4
TLMI-1
TLMI-2
TLMI-3
TLMI-4
17
15
13
11
BR-R
G-R
O-R
BL-R
Env. Input - #5
Env. Input - #6
Env. Input - #7
Env. Input - #8
TLMI-5
TLMI-6
TLMI-7
TLMI-8
7
5
3
1
BR-W
G-W
O-W
BL-W
Env. Input - #9
Env. Input - #10
Env. Input - #11
Env. Input - #12
TLMI-9
TLMI-10
TLMI-11
TLMI-12
Env. Input - #21
Env. Input - #20
TLMI-21
TLMI-20
16
14
12
10
R-G
R-O
R-BL
W-S
Env. Input - #13
Env. Input - #14
Output - Common
Env. Output - #1
TLMI-13
TLMI-14
TLMO-C
TLMO-1
Env. Input - #19
Env. Input - #18
TLMI-19
TLMI-18
8
6
21
19
W-BR
W-G
BL-BK
S-R
Env. Output - #2
Env. Output - #3
Env. Output - #4
No Connection
TLMO-2
TLMO-3
TLMO-4
NC Env. Input - #16 TLMI-16
24
22
20
2
BK-O
BK-BL
R-S
W-BL