363-206-204
Release 13 (TARP) Installation Tests
â–
At-sign (@) — Erases the current line.
â–
CANcel, and DELete — Terminates the current input line or currently run-
ning command.
â–
Hyphen (-) — Separates identifiers in the command mode.
â–
Colon (:) — Separates parameter blocks in a command.
â–
Comma (,) — Separates parameters within a parameter block in a com-
mand.
Login Procedure
1. Connect one of the approved terminals (properly configured) to an EIA-
232D port on one of the DDM-2000 OC-3s in the bay.
NOTE
:
If properly cabled, connection to any EIA-232D in the bay will allow com-
munication to any shelf in the bay.
2. Press the Return
(or Enter) key twice, to set the SYSCTL autobaud rate
and prompt the DDM-2000 OC-3 to request a shelf address.
The DDM-2000 OC-3 will respond:
/* Enter a shelf number from 1 to 8 */
shelf [default] =
NOTE
:
The default shelf is the one physically connected to the CIT. To determine
what shelves can be entered enter a
?
.
3. After entering a valid shelf number and pressing the return (or Enter) key
the user is presented with:
login<
NOTE
:
If the Return (or Enter) key is pressed without entering a shelf number the
shelf to which you are physically attached will be accessed.
NOTE
:
There is a special login and password already programmed into the system
for use during the execution of these tests. The login is
LUC01
and the
password is
DDM-2000
. For circuit packs and shelves manufactured up to,
but not including,1 October 1996, the login is
ATT01
.
This older login may
have been upgraded to
LUC01
if newer software has been installed. Both
login and password must be UPPERCASE