EasyManuals Logo

Manitowoc MLC650 Service Maintenance Manual

Manitowoc MLC650
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Reference Only
ELECTRICAL SYSTEM MLC650 SERVICE/MAINTENANCE MANUAL
3-44
Published 09-09-16, Control # 229-09
Table 3-17. IOLC32 Test Voltages
Pin I/O Network Function Voltages
PC1-1 GND Ground (from ground stud on rotating bed)
0V
DC
PC1-2 KL15 Control Module Ignition Power (from engine run switch)
0V
DC
Open, 24 V
DC
Closed
PC1-3 ID01 Hydraulic Charge Filter Alarm Pressure Switch
0V
DC
Open, 24 V
DC
Closed
PC1-4 No Connection
PC1-5 OPH6A18 Drum 3/2 Pump 2
0V
DC
Open, 24 V
DC
Closed
PC1-6 OPH6A19 Drum 3/2 Pump 2
0V
DC
Open, 24 V
DC
Closed
PC1-7 OPH6A20 Right Travel/Drum 2 Pump 4
0V
DC
Open, 24 V
DC
Closed
PC1-8 OPH6A21 Right Travel/Drum 2 Pump 4
0V
DC
Open, 24 V
DC
Closed
PC1-9 IMID1 Module Identifier Input (from ground stud on rotating bed)
0V
DC
PC1-10 CAN1_H CAN Bus C—High Not Applicable
PC1-11
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC1-12
+U
E
Control Module Battery Power
24 V
DC
PC1-13 No Connection
PC1-14 No Connection
PC1-15 No Connection
PC1-16 ID06 VPC Tray Max In Switch
0V
DC
Open, 24 V
DC
Closed
PC1-17 IDF15 Not Used—For Possible Future Expansion
0V
DC
PC1-18 No Connection
PC1-19 CAN1_L CAN Bus C—Low Not Applicable
PC1-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC1-21 ID07 Hydraulic Vacuum Switch
0V
DC
Open, 24 V
DC
Closed
PC1-22 ID08 Drum 4 Pawl Limit Switch
0V
DC
Open, 24 V
DC
Closed
PC1-23 ID09 Active Fixed Mast Stop System Connected
0V
DC
Not Installed, 24 V
DC
Installed
PC1-24 ID10 Not Used—For Possible Future Expansion
0V
DC
PC1-25 ID11 Not Used—For Possible Future Expansion
0V
DC
PC1-26 IDF16 Not Used—For Possible Future Expansion
0V
DC
PC1-27 IACV17 Hydraulic Fluid Temperature Sensor
0.5 to 4.5 V
DC
PC1-28 IMID4 Module Identifier Input (from ground stud on rotating bed)
0V
DC
PC1-29 IMID3 Module Identifier Input (from ground stud on rotating bed)
0V
DC
PC2-1 ID12 Not Used—For Possible Future Expansion
0V
DC
PC2-2 ID13 Not Used—For Possible Future Expansion
0V
DC
PC2-3 No Connection
PC2-4 IACV18 Hydraulic Fluid Level Sensor
1V
DC
Full, 9 V
DC
Empty
PC2-5 ODH3A02 Drum 4 Pawls Out Solenoid
0V
DC
Off, 24 V
DC
On

Table of Contents

Other manuals for Manitowoc MLC650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc MLC650 and is the answer not in the manual?

Manitowoc MLC650 Specifications

General IconGeneral
BrandManitowoc
ModelMLC650
CategoryConstruction Equipment
LanguageEnglish

Related product manuals