Manitowoc Published 09-09-16, Control # 229-09 3-51
MLC650 SERVICE/MAINTENANCE MANUAL ELECTRICAL SYSTEM
3
PC2-15 ODH31A01
Power Bus:
VPC-MAX Tray Maximum In
VPC-MAX Tray Maximum Out
VPC-MAX Beam Level Sensor
0V
DC
Open, 24 V
DC
Closed
PC2-16 No Connection
PC2-17 ODH3A09 Beam/Foot Upper Pin Extend
0V
DC
Off, 24 V
DC
On
PC2-18 OPH3A14 Not Used—For Possible Future Expansion
0V
DC
PC2-19 OPH3A17 Not Used—For Possible Future Expansion
0V
DC
PC2-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC2-21 No Connection
PC2-22 IACV21 VPC-MAX Beam Level Sensor (pitch)
5.025 V
DC
@ 0°
±1.005 V
DC
Offset/°
PC2-23 IACV22 VPC-MAX Beam Level Sensor (roll)
5.025 V
DC
@ 0°
±1.005 V
DC
Offset/°
PC2-24 ODH3A03 VPC Actuator Pin Retract
0V
DC
Off, 24 V
DC
On
PC2-25 No Connection
PC2-26 ODH3A08 VPC-MAX Actuator Encoder
0V
DC
Off, 24 V
DC
On
PC2-27 ODH3A11 Beam/Foot Lower Pin Extend
0V
DC
Off, 24 V
DC
On
PC2-28 ODH3A13 Not Used—For Possible Future Expansion
0V
DC
PC2-29 ODH3A16 Not Used—For Possible Future Expansion
0V
DC
Pin I/O Network Function Voltages

Table of Contents

Other manuals for Manitowoc MLC650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc MLC650 and is the answer not in the manual?

Manitowoc MLC650 Specifications

General IconGeneral
BrandManitowoc
ModelMLC650
CategoryConstruction Equipment
LanguageEnglish

Related product manuals