Manitowoc Published 09-09-16, Control # 229-09 3-31
MLC650 SERVICE/MAINTENANCE MANUAL ELECTRICAL SYSTEM
PC1-34 IMID2 Module Identifier Input (from ground stud on rotating bed)
0V
DC
PC1-35 IDF02 VPC Actuator Left Motor Speed Sensor Not Applicable
PC1-36 IDF07 VPC Right Motor Speed Sensor
Input Voltage—0.5 V
DC
Over Tooth
0 to 0.5 V
DC
Over Gap
PC1-37 IDF08 VPC Right Motor Speed Sensor
Input Voltage—0.5 V
DC
Over Tooth
0 to 0.5 V
DC
Over Gap
PC1-38 IACV15 Left Track Pressure Transducer
4mA @ 0psi
20 mA @ 7,500 psi
PC1-39 IACV13 Right Track Pressure Transducer
4mA @ 0psi
20 mA @ 7,500 psi
PC1-40 IACV12 Swing Left Pressure Transducer
4mA @ 0psi
20 mA @ 7,500 psi
PC1-41 OS85H Not Used—For Possible Future Expansion
8.5 V
DC
PC1-42 OPH3A26 Right Front Jack Retract Solenoid
0V
DC
Off, 24 V
DC
On
PC2-1 PGND1 Ground (from ground stud on rotating bed)
0V
DC
PC2-2 ODH3A03 Rear Frame Pusher Pin Extend Solenoid
0V
DC
Off, 24 V
DC
On
PC2-3 No Connection
PC2-4 ODH3A08
Power Bus:
• Mast Arm NC Limit Switch
• VPC Actuator Extend Pressure
Transducer
• Accessory Systems Pressure Transducer
24 V
DC
PC2-5 ODH3A05 Not Used—For Possible Future Expansion
0V
DC
PC2-6 ODH3A13 Left Track Drum 1 Diverter Solenoid
0V
DC
Off, 24 V
DC
On
PC2-7 ODH3A15 Drum 1 Drum 6 Diverter Solenoid
0V
DC
Off, 24 V
DC
On
PC2-8 No Connection
PC2-9 No Connection
PC2-10 PGND2 Ground (from ground stud on rotating bed)
0V
DC
PC2-11
+U
B
SW1
Battery Power for Control Module Outputs
24 V
DC
PC2-12 OPH3A24 Left Front Jack Retract Solenoid
0V
DC
Off, 24 V
DC
On
PC2-13 ODH3A01
Power Bus:
• Swing Right Pressure Transducer
• Swing Left Pressure Transducer
• Right Track Pressure Transducer
• Left Track Pressure Transducer
24 V
DC
PC2-14 ODH3A07 Not Used—For Possible Future Expansion
0V
DC
PC2-15 ODH3A06 Not Used—For Possible Future Expansion
0V
DC
Pin I/O Network Signal Voltages