0850/0850-T1 User Manual
Matrix Machine Tool (Coventry) Limited 161 / 231
Edition: 08/2013
Active Correction
Read Only field.
This field shows the calculated amount of correction that has been applied to the machine based on
the input values for Lead error and Error length.
Active Lead
Read Only field.
This field shows the re-calculated lead that has been applied to the machine based on the input
values for Lead error and Error length.
19.17.2 Procedure
To add Lead Correction
1. Select [AUTO] and [SETUP] mode
2. Select the Correction utilities screen [Custom > Matrix > Main Menu > Setting Cycles >
Correction Utilities]
3. Select the [Lead Correction] softkey.
4. Input the measured lead error (microns) followed by pressing the yellow [Input] key.
5. Press [Update Correction] vertical softkey
To reset the active lead correction
Press the [Reset Correction] softkey.