0850/0850-T1 User Manual
Matrix Machine Tool (Coventry) Limited 167 / 231
19.19 Diameter Correction
This utility allows small adjustments to be applied to the machine to correct for diameter error found
after the ground workpiece has been measured.
19.19.1 Explanation of input parameters
Diameter Error
Input Range: 0 - 999 microns
Error between the measured diameter and the active machine diameter
Tooth Error
Input Range: 0 - 999 microns
Error between the measured tooth width and required tooth width.
This input field only applicable when grinding dual-lead worms.