0850/0850-T1 User Manual
Matrix Machine Tool (Coventry) Limited 221 / 231
700xxx Probe unexpected hit – cycle aborted
Cause:
During the probe slide advance sequence, the probe trigger signal was detected indicating a
deflection of the probe stylus had occurred.
Remedy:
No probe stylus deflection should occur while the probe is being moved to the advanced or
retracted position.
Check for obstacles in the path of the probe slide that could have initiated a probe stylus
deflection.
700033 Programmed wheel speed is too high
Cause:
The programmed wheel speed is above the maximum wheel speed defined in the Matrix Setup
Data screen
Remedy:
Reduce the programmed wheel speed to below the maximum wheel speed. Wheel Speed changes
should only be Performed while the wheel is Stopped.
700034 Coolant system not started
Cause:
An attempt has been made to execute an NC program before the coolant system has been started
up.
Remedy:
Start the coolant system and check that the red fault indicator is not illuminated at the coolant
system control panel.
Check coolant centrifuge pump motor is operating
Check coolant centrifuge unit is operating
Check there is enough coolant in the tank