700114 Machine air supply pressure is low
Cause:
The main air supply pressure to the machine has reached a pressure below the minimum level
required to operate the machine.
Either there is not enough pressured air being supplied to the machine and/or the main air
pressure solenoid has failed to operated.
Remedy:
Check main air isolator is turned to the on position.
Check air pressure supply to the machine is between 5.5 6.8bar.
Check fuse that protects the air pressure solenoid circuit.
700116 Scale air purge pressure low
Cause:
The air supply pressure to the measuring system has reached a pressure below the minimum level
required to purge the X and Z axis linear encoders.
Remedy:
Check main air isolator is turned to the on position.
Check air pressure supply to the machine is between 5.5 6.8bar.
Check fuse that protects the air purge solenoid circuit.
700117 Coolant tank level too high
Cause:
There is too much coolant oil in the tank when the coolant system is in normal operation.
The coolant high level float switch could have become stuck.
Remedy:
Check the amount of coolant oil in the tank and siphon off excess coolant from the tank if
necessary.
Check the high level float switch operates correctly or replace it.