27 - 60
27.3 CC-Link Connection (Intelligent Device Station)
27.3.10 CNC Side Settings
(2) Setting description
*1 Set as necessary.
*2 Set the station No. not to overlap with that of other units.
For details of the parameter setting, refer to the following.
MELDAS C6/C64 NETWORK MANUAL BNP-B2373
No. Switch name Settings
1)
Condition setting
switch
This switch sets the operation conditions.
No. Description
Switch status Setting validity
OFF ON
Master station
(Standby
master station)
Local station
(Standby
master station)
SW1
Station type
*1
Master station/local station Standby master station (Valid) (Valid)
SW2 (Not used) Always OFF
SW3 (Not used) Always OFF
SW4
Data link error
station input data
status
*1
Clear Hold Valid Valid
SW5
Number of
occupied
stations
*1
OFF
1
station
OFF
2
sta-tions
ON
3
sta-tions
ON
4
sta-tions
Invalid Valid
SW6 OFF ON ON OFF
SW7
(Not used)
Always OFF
SW8
(Not used)
Always OFF
2)
Mode setting switch`
This switch sets the unit operation status.
No. Name Description
Settability
Master station Local station
0
Online
*1
Automatic online return provided when data link is
enabled
Yes Yes
1 Link with remote I/O net mode Yes No
2
Offline
*1
Data link offline state Yes Yes
3
Line test 1
*1
Line test 1 in offline state Yes No
4
Line test 2
*1
Line test 2 in offline state Yes No
5
Parameter
confirmation test
*1
Checks the parameter details Yes No
6
Hardware test
*1
Test Expansion unit (FCU6-HR865) Yes Yes
7 to F Not usable
3)
Transmission speed
setting switch
This switch sets the unit transmission speed.
No. Description
0
156Kbps
*1
1
625Kbps
*1
2
2.5Mbps
*1
3
5Mbps
*1
4
10Mbps
*1
5 to F Not usable
4)
Setting switch of
station No.
This switch sets the unit station No. *1*2
<Setting range>
Master station : 00 Local station : 01 to 64
Standby master station : 01 to 64
If a value other than 00 to 64 is set, the "SW" and "L.ERR." LED will turn ON.