31 - 18
31.2 Preparatory Procedures for Monitoring
31.2.7 Checking for normal monitoring
(2) When using the "PING Test" of GT Designer2
Select [Communication] [Communication configuration] "Ethernet" and to display
"PING Test".
(3) When abnormal communication
At abnormal communication, check the followings and execute the Ping command again.
Mounting condition of Ethernet communication unit
Cable connecting condition
Confirmation of "Communication settings"
IP address of GOT svpecified by Ping command
Ethernet diagnostics of GX Developer
Ethernet diagnostics of GX Developer is available to a Ping test from the PLC.
For details of Ethernet diagnostics of GX Developer, refer to the following manual.
User's Manual of the Ethernet module
If all the communication settings are completed
Set up the gateway function to be used.
GOT1000 Series Gateway Functions Manual
All settings related to communications are complete now.
Create screens on GT Designer2 and download the project data again.
Test
1 Specify the "GOT IP address" of the
"PING Test" and click on the
button.
2 The "Test Result" is displayed after the
"PING Test" is finished.
PING Test

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT1000 Series and is the answer not in the manual?

Mitsubishi GOT1000 Series Specifications

General IconGeneral
Power Supply24 VDC
TypeHMI (Human Machine Interface)
SeriesGOT1000
Resolution640 x 480 pixels
Touch Panel TypeResistive
InterfaceRS-232, USB
Storage Temperature-20 to 60°C
Protection RatingIP65
Display TypeTFT LCD
Brightness400 cd/m²
Backlight Life50, 000 hours
CPURISC
Shock Resistance147 m/s²
Display Size10.4 inches

Related product manuals