19.5  Message Formats
19.5.3  Formats 1, 2 (GOT-A900 series microcomputer connection)
19 - 37
17
CONNECTION TO 
ALLEN-BRADLEY PLC
18
CONNECTION TO 
SIEMENS PLC
19
MICROCOMPUTER 
CONNECTION
20
CONNECTION TO OMRON 
TEMPERATURE 
CONTROLLER
21
CONNECTION TO 
YAMATAKE TEMPERATURE 
CONTROLLER
22
CONNECTION TO RKC 
TEMPERATURE 
CONTROLLER
23
CONNECTION TO 
FREQROL SERIES 
INVERTER
24
SERVO AMPLIFIER 
CONNECTION
(5) Read clock data (TR) command
The following shows an example of reading the clock data of GOT.
(Assuming that the clock data of GOT has been set to "2004, June 1, 18:46:49, Tuesday".)
Item Message format
Request message
(host  GOT)
Response 
message during 
normal 
communication
(GOT  host)
Response 
message during 
faulty 
communication
(GOT  host)
(format 1: GOT-A900 series microcomputer connection (format 1))
(format 2: GOT-A900 series microcomputer connection (format 2))
Time display
2004/06/01 18:46:49
TUE
Sum check is performed in this range.
02
H
STX
03
H
ETX
(H) (L)
A9
41
H 39H
Sum
Check
(H) (L)
Command
TR
54
H 52H
Sum check is performed in this range.
02
H
STX
03
H
ETX
(H) (L)
D0
44
H 30H
Sum
Check
(H) (L)
Year data
04
30
H 34H
(H) (L)
Month data
06
30
H 36H
(H) (L)
Day data
01
30
H 31H
(H) (L)
Hour data
18
31
H 38H
(H) (L)
Minute data
46
34
H 36H
(H) (L)
Second  
data
49
34
H 39H
(H) (L)
Day-of- 
week data
02
30
H 32H
15H
NAK
The above is a case where  
the sum check error (06
H)  
has occurred.
15
H
NAK
06
H
Error  
code