NICE3000
new
User Manual
5 Use of the Commissioning Tools
- 107 -
◆
Saving and Restoring
After you change the value of any function parameter and press
to save the setting, the
NICE3000
new
stores the changed value locally so that the change remains effective when you power on the
controller next time. The NICE3000
new
also stores alarm information and cumulative running time statistics.
You can also restore the default parameter settings, or clear the running data by using the function
parameter FP-01.
Function Code Parameter Name Setting Range
FP-01 Parameter update
0: No operation
1: Restore default settings (except group F1)
2: Clear fault records
If you set this parameter to 1 (Restore default settings), all parameters except group F1 are restored to the
default settings. Be cautions with this setting.
◆
Password Security
The NICE3000
new
controller provides a security protection function that requires a user-dened password.
Function parameter FP-00 implements this function.
To enable the password protection, do as follows:
●
Set a non-zero value for FP-00. This value is the user-dened password.
●
Make a written note of the value you have set for FP-00 and keep the note in a safe location.
Remember the password that you set. If the password is forgotten, contact us to replace the
control board.
●
Press
to save the setting and exit the function parameter editing mode.
The password protection is successfully enabled. Then when you press
, the display shows "-----".
You must enter the correct password to enter the programming menu.
To cancel password protection, do as follows:
●
Use the current password to enter the function parameter editing mode.
●
Set FP-00 to zero.
●
Press
to save the setting and exit the function parameter editing mode.