7 Function Code Table NICE3000
new
User Manual
- 168 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
F3-16
Position of up slow-
down 3
0.000–300.00 0.00 m
202
F3-17
Position of down slow-
down 3
0.000–300.00 0.00 m
202
F3-18
Zero-speed control
time at startup
0.000–1.000 0.200 s
201
F3-19 Brake release delay 0.000–2.000 0.600 s
201
F3-20
Zero-speed control
time at end
0.000–1.000 0.300 s
201
F3-21
Low-speed re-leveling
speed
0.080 to F3-11 0.100 m/s
193
F3-22
Acceleration rate
at emergency
evacuation
0.100–1.300 0.100 m/s
2
219
F3-24
Slip experiment
function
0: Disabled
1: Enabled
0 -
202
Group F4: Floor parameters
F4-00 Leveling adjustment 0–60 30 mm
252
F4-01 Current oor F6-01 to F6-00 1 -
202
F4-02
High byte of current
oor position
0–65535 1 Pulses
202
F4-03
Low byte of current
oor position
0–65535 34464 Pulses
202
F4-04
Length 1 of leveling
plate
0–65535 0 Pulses
203
F4-05
Length 2 of leveling
plate
0–65535 0 Pulses
203
F4-06
High byte of oor
height 1
0–65535 0 Pulses
203
F4-07
Low byte of oor
height 1
0–65535 0 Pulses
203
F4-08
High byte of oor
height 2
0–65535 0 Pulses
203
F4-09
Low byte of oor
height 2
0–65535 0 Pulses
203
F4-10
High byte of oor
height 3
0–65535 0 Pulses
203
F4-11
Low byte of oor
height 3
0–65535 0 Pulses
203
F4-12
High byte of oor
height 4
0–65535 0 Pulses
203
F4-13
Low byte of oor
height 4
0–65535 0 Pulses
203
F4-14
High byte of oor
height 5
0–65535 0 Pulses

Table of Contents