7 Function Code Table NICE3000
new
User Manual
- 174 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
F6-09
Elevator program
control
Bit0: Dispersed waiting
Bit3: Parallel/Group control
implemented at CAN2
Bit4: Group control in compatibility
with NICE3000
Bit6: Clear oor number and
display direction in advance
Bit8: Unidirectional hall call (single
hall call button)
Bit 9: Not detecting analog wire
breaking
Bit10: Err30 judgment at re-
leveling cancellation
Bit14: Time interval detection
of safety circuit 2 and door lock
circuit 2
0 -
217
F6-10
Leveling sensor lter
time
10–50 14 ms
221
F6-11
Elevator function
selection
Bit1: Disabling returning to base
oor for verication
Bit2: Cancelling auto sequential
arrange of hall call oor addresses
to be displayed
Bit5: Current detection valid at
startup for synchronous motor
Bit6: Reversing MCB lamp output
Bit7: Door open valid at non-door
zone in the inspection state
Bit8: Door open and close once
after inspection turned to normal
Bit10: Buzzer not tweet upon re-
leveling
Bit11: Super short oor function
Bit12: Fault auto reset
Bit13: Err53 fault auto reset
Bit14: Up slow-down not reset for
super short oor
Bit15: Down slow-down not reset
for super short oor
8448 -
221
F6-12 VIP oor 0 to F6-00 0 -
220
F6-13 Security oor 0 to F6-00 0 -
223
F6-14
Start time of down
collective selective 1
00.00–23.59 00.00 HH.MM
217
F6-15
End time of down
collective selective 1
00.00–23.59 00.00 HH.MM
217

Table of Contents

Related product manuals