7 Function Code Table
- 177 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
F6-42
Program control
selection 3
Bit1: Cancelling door open/close
command at delay after door
open/close limit
Bit2: Not judging door lock state
at door close output
Bit3: Door close command output
during running
Bit4: Returning to base oor for
verication at rst-time power-on
Bit5: Clearing calls immediately at
elevator lock
0 -
221
F6-43
Attendant function
selection
Bit0: Calls cancelled after entering
attendant state
Bit1: Not responding to hall calls
Bit2: Attendant/Automatic state
switchover
Bit3: Door close at jogging
Bit4: Automatic door close
Bit5: Buzzer tweeting at intervals
in attendant state
Bit6: Buzzer tweeting at intervals
in attendant state
Bit7: Car call button blinking to
prompt
0 -
218
F6-44
Fire emergency
function selection
Bit3: Arrival gong output in
inspection or re emergency state
Bit4: Multiple car calls registered
in re emergency state
Bit5: Retentive at power failure in
re emergency state
Bit6: Closing door by holding
down the door close button
Bit8: Door close at car call
registering
Bit9: Displaying hall calls in re
emergency state
Bit10: Fireghter forced running
Bit11: Exiting reghter state upon
arrival at re emergency oor
Bit12: Not clearing car calls at
reverse door open in reghter
running state
Bit14: Opening door by holding
down the door open button
Bit15: Automatic door open at re
emergency oor
16456 -
222

Table of Contents