9 Troubleshooting NICE3000
new
User Manual
- 276 -
9
Fault
Code
Name Possible Causes Solution
Level
Err35
Shaft auto-
tuning data
abnormal
Subcode 105: The
elevator running direction
and the pulse change are
inconsistent.
Subcodes 106, 107, 109:
The plate pulse length
sensed at up/down
leveling is abnormal.
Subcodes 108, 110: No
leveling signal is received
within 45s continuous
running.
Subcodes 111, 115: The
stored oor height is
smaller than 50 cm.
Subcode 112: The oor
when auto-tuning is
completed is not the top
oor.
(End)
Subcode 105:
Check whether the elevator running direction
is consistent with the pulse change in F4-
03: F4-03 increases in up direction and
decreases in down direction. If not, change
the value of F2-10 to ensure consistency.
Subcode 106, 107, 109:
Check that NO/NC state of the leveling
sensor is set correctly.
Check whether the leveling plates are
inserted properly and whether there is
strong power interference if the leveling
sensor signal blinks.
Check whether the leveling plate is too
long for the asynchronous motor.
Subcodes 108, 110:
Check whether wiring of the leveling
sensor is correct.
Check whether the oor distance is too
large, causing running time-out. Increase
the speed set in F3-11 and perform shaft
auto-tuning again to ensure that learning
the oors can be completed within 45s.
Subcodes 111, 115:
Enable the super short oor function if the
oor distance is less than 50 cm. If the oor
distance is normal, check installation of the
leveling plate for this oor and check the
sensor.
Subcode 112:
Check whether the setting of F6-00 (Top oor
of the elevator) is smaller than the actual
condition.
(End)