Function List
1. Basic functions
Function Description Remarks
Common Running Functions
Integrated control
for synchronous and
asynchronous motors
The NICE3000
new
can drive both AC asynchronous motor and
PMSM.
Switchover between
the two types of
motors easily by
modifying F1-25
Full collective selective
In automatic running or attendant state, this function enables
the elevator to respond both car calls and hall calls. Passengers
at any service oor can call the elevator by pressing the up call
button and down call button.
FE-00 (Collective
selective mode)
Service oor
The standard program supports 40 oors. The service of more
than 40 oors is supported by the customized program.
-
Door open time setting
The system automatically determines different door open time
for door open for call, command, protection, or delay according
to the set door open holding time.
Set in group Fb
Door open delay
In automatic running state, passengers can press the door open
button in the car to delay door open to facilitate goods to be
moved in or out.
Fb-14 (Door open
holding time at such
signal input)
Door machine service
oor setting
You can set the required service oors of the door machines.
Fb-02, Fb-03, Fb-04,
Fb-05
Door pre-close by the
door close button
During door open holding in automatic running state,
passengers can press the door close button to close the door in
advance, which improves the efciency.
-
Floor number display
setting
The system supports display of oor numbers in combinations
of numbers and letters, which meets the requirements of special
conditions.
Set in group FE
Light curtain signal
judgment
If the door is blocked by stuff during door close, the light curtain
acts and the elevator opens the door. This function is invalid in
re emergency state.
-
Auxiliary operation box
An optional auxiliary operation box that has the same functions
as the main operation box is available.
-
Independent control of
the front door and back
door
When there are two doors for a car, automatic control on the two
doors depends on your requirements.
Refer to section 6.2.4
Repeat door close
If the door lock is not applied after the elevator performs door
close for a certain time, the elevator automatically opens the
door and then closes the door again.
Fb-08 (Door close
protection time)
Independent command
When the main and auxiliary operation boxes are congured,
they can independently control door open/close according to the
commands in automatic running state.
-
Voice announcement
The elevator automatically announces information such as the
running direction and next arriving oor during running.
MCTC-CHM required
Auto-leveling
The systems implements automatic accurate leveling based on
the oor pulse counting and up/down leveling feedback signals.
-
Response at
acceleration
The system allows the elevator to automatically respond to calls
from the service oors during acceleration.
-
Down collective
selective control
In automatic running or attendant state, the elevator responds