Troubleshooting VJ-1617H OPERATION MANUAL
7-16
16 Measurement Error
(Take Up Roll)
The setting in Take-up Unit
Menu is [Type1].
Change the setting to [Off].
5.3.3 Take-
up unit menu
17 Measurement Error
(Media Detection)
The setting in Media
Detection Menu is [Off].
Change the setting to
[Height+Width] or
[Height+Width].
5.2.2.7 Medi
a Initial menu
18 Measurement Error
(Media Width)
The width of the mounted
media does not match the
color target to be measured.
Remove the mounted media
and set the correct color
target.
3.5 Setting
media
19 Measurement Error
(Command)
The parameters sent from RIP
software are abnormal.
Check the color calibration of
the RIP software and its color
profiling setting.
—
20 Measurement Error
(Out Of Media)
Media ran out during printing
or measurement of the color
target.
Set new media and start
printing and measuring the
color target again.
4.6 Using
Spectrophotomet
er
(SPECTROVUE
VM-10)
21 Measurement Error
(Cover Open)
Cover opened while the color
target was being measured.
Make sure to close Front
Cover and Maintenance
Cover on the left side of the
printer.
3.5 Setting
media
6.2.1 Cleanin
g the cleaning
wiper unit
6.2.2 Cleanin
g around the print
head
22 Measurement Error
(Lever Lifted)
Media Set Lever was lifted
while printing or measuring
the color target.
Printing or measuring will be
cancelled. Start printing and
measuring the color target
again.
4.6 Using
Spectrophotomet
er
(SPECTROVUE
VM-10)
23 Measurement Error
(Communication)
There was a communication
error with the computer while
printing or measuring the
color target.
Check the communication
requirements between the
printer and computer.
3.8 Connecti
ng the printer to
PC
24 Measurement Error
(Instrument)
There was a communication
error with Spectrophotometer
(SPECTROVUE VM-10)
while printing or measuring
the color target.
Check the connection
between the printer and
Spectrophotometer
(SPECTROVUE VM-10).
4.6 Using
Spectrophotomet
er
(SPECTROVUE
VM-10)
25 Measurement Error
(Cancelled)
Printing or measuring of the
color target has been
cancelled from the operation
panel or RIP software.
Start printing and measuring
the color target again.
4.6 Using
Spectrophotomet
er
(SPECTROVUE
VM-10)