5.3 Explanation of Each Program Message
BP4610
5-10
WAVE /WAVE ?
Description: Selects the superimposed current waveform.
Parameter: 0: SIN (sine wave)
1: SQU (square wave)
2 to 17: ARB1 to ARB16 (arbitrary waveform)
Setting example: Setting the waveform to be output to sine wave
WAVE 0
Caution: Setting cannot be performed when output is on.
5.3.2 Limiter
LMCM/LMCM?
Description: Sets the current limiter.
Parameter: Current [A]
26.0 to 1.0
Setting example: Setting the – current limiter to 15 A
LMCM 15
Caution: Settable in units of 0.1 A
LMCP/LMCP?
Description: Sets the + current limiter.
Parameter: Current [A]
1.0 A to 26.0 A
Setting example: Setting the + current limiter to 15 A
LMCP 15
Caution: Settable in units of 0.1 A
LMVM/LMVM?
Description: Sets the – voltage limiter.
Parameter: Voltage [V]
117.0 V to 7.0 V
Setting example: Setting the – voltage limiter to –100 V
LMVM 100
Caution: Settable in units of 0.1 A
LMVP/LMVP?
Description: Sets the + voltage limiter.
Parameter: Voltage [V]
7.0 V to 117.0 V
Setting example: Setting the + voltage limiter to 100 V
LMVP 100
Caution: Settable in units of 0.1 V