8.5 Monitor Output
BP4610
8-6
8.5 Monitor Output
Output voltage monitor output
Monitor ratio: 1/100 of output voltage (1 V/100 V), in phase
Monitor accuracy: ±1.2 V (difference between DC output voltage and
conversion voltage obtained from monitor voltage, 1 MΩ
monitor output load impedance)
Frequency characteristics: DC to 40 kHz ±0.5 dB
40 kHz to 400 kHz +1 dB, −3 dB
(1 kHz reference, 1 MΩ monitor output load impedance)
Output impedance: 50 Ω
Output terminal: BNC connector (front panel)
Output current monitor output
Monitor ratio: 1/10 of output current (1 V/10 A), in phase
Monitor accuracy: ±0.2 A (difference between DC output current and
conversion current obtained from monitor voltage, 1 MΩ
monitor output load impedance)
Frequency characteristics: DC to 20 kHz ±0.5 dB
20 kHz to 200 kHz +1 dB, −3 dB
(1 MΩ monitor output load impedance)
Output impedance: 50 Ω
Output terminal: BNC connector (front panel)
8.6 Measurement Functions
DC output voltage measurement (Measures AC + DC average. However, AC + DC
must be within ±200 V.)
Full scale: ±200 V (0.1 V resolution)
Measurement accuracy: ±0.5 V (within DC ±115 V, 0 V AC)
DC output current measurement (Measures AC + DC average. However, AC + DC
must be within ±20 A.)
Full scale: ±20 A (0.01 A resolution)
Measurement accuracy: ±0.1 A (within DC ±10 A, 0 A AC)
AC output voltage measurement (Measures max. value of ACTDC − Min. value of
AC + DC. However, AC + DC must be within ±200 V.)
Full scale: 400 Vp-p (1 Vp-p resolution)
Measurement accuracy: ±2 Vp-p (DC 0 V, 120 Vp-p, 500 Hz)
Measurement frequency band: 10 kHz/−3 dB
AC output current measurement (Measures max. value of AC + DC − Min. value
of AC + DC. However, AC + DC must be within ±20 A.)
Full scale: 40 Ap-p (0.1 Ap-p resolution)
Measurement accuracy: ±1 Ap-p (0 A DC, 30 Ap-p, 500 Hz)
Measurement frequency band: 10 kHz/−3 dB