Maximum Applicable Motor Capacity
037 3.7 kW
055 5.5 kW
075 7.5 kW
110 11 kW
150 15 kW
185 18.5 kW
220 22 kW
300 30 kW
370 37 kW
450 45 kW
550 55 kW
750 75 kW
11K 110 kW
16K 160 kW
18K 185 kW
22K 220 kW
30K 300 kW
Voltage Class
2 Three-phase 200-V AC input (200-V class)
4 Three-phase 400-V AC input (400-V class)
Enclosure Rating
A Panel-mounting (IP10 min.) or closed wall-mounting model
B Panel-mounting (IP00)
D Checking for Damage
Check
the overall appearance and check for damage or scratches resulting from transportation.
Check
that parts connected by screws are securely fastened.
H Checking the Accessories
Note
that this manual is the only accessory provided with the 3G3HV
.
Set screws and other necessary
parts must be provided by the user.