Caution Install
external breakers and take other safety measures against short-circuiting in
external wiring. Not doing so may result in fire.
Caution Confirm
that the rated input voltage of the Inverter is the same as the AC power sup
-
ply voltage. An incorrect power supply may result in fire, injury, or malfunction.
Caution Connect
the Braking Resistor and Braking Resistor Unit as specified in the manual.
Not doing so may result in fire.
Caution Be
sure to wire correctly and securely
. Not doing so may result in injury or damage
to
the product.
Caution Be
sure
to firmly tighten the screws on the terminal block. Not doing so may result in
fire, injury, or damage to the product.
Caution Do
not connect an AC power to the U, V
, or W output. Doing so may result in
damage
to the product or malfunction.
Operation and Adjustment Precautions
WARNING Turn
ON the input power supply only after mounting the front cover
, terminal covers,
bottom cover, Operator, and optional items. Not doing so may result in electrical
shock.
WARNING Do
not remove the front cover
, terminal covers, bottom cover
, Operator
, or optional
items
while the power is being supplied. Not doing so may result in electrical shock or
damage to the product.
WARNING Do not operate the Operator or switches with wet hands. Doing so may result in
electrical shock.
WARNING Do not touch the inside of the Inverter. Doing so may result in electrical shock.
WARNING Do
not come close to the
machine when using the error retry function because the
machine
may abruptly start when stopped by an alarm. Doing so may result in injury
.
WARNING Do not come close to the machine immediately after resetting momentary power
interruption
to avoid an unexpected restart (if operation is set to be continued in the
processing
selection function after momentary power interruption is reset). Doing
so
may result in injury.
WARNING Provide
a separate emergency stop switch because the ST
OP Key on the Operator
is
valid
only when function settings are performed. Not doing so may result in injury
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3HV SERIES and is the answer not in the manual?

Omron SYSDRIVE 3G3HV SERIES Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE 3G3HV SERIES
CategoryInverter
LanguageEnglish

Related product manuals