1-8
quency
is compensated accordingly
. By using the slip compensation function, speed fluctuations of the
load can be reduced more effectively than with previous models.
H Changing Parameters while Inverter is Running
It
is now possible to change some
parameters and, related to this, monitor and set the items in the bot
-
tom
two lines of
easy-setting indicators while the Inverter is running. Using this feature, set values for
some
parameters can be adjusted while monitoring operation. For details of which parameters can be
changed while the Inverter is running, refer to the parameter lists.
H Operation Selection at Digital Operator Interruption Function (n112)
A
function that detects communications errors between the Digital Operator and the Inverter itself, and
interrupts Inverter outputs has been added.
H Settable Detection Width (n113)
The
detection width of the optional frequency agreement and
the optical frequency detection can be set
with parameters. With previous models this setting was fixed.
H Operation Selection at Operation Mode Switching (Local/Remote
Switching) (n114)
Using
the Operation Mode Selection Key on the Digital Operator or operation mode selection input set
using the multi-function input parameters (set value: 5), it is possible to switch between operation from
the
Digital Operator and operation according
to the setting of the operation mode selection parameter
(n002). A function that selects whether run signals input while the operation mode is switching are
enabled or disabled after the mode has changed, has been added.
Note If
this setting is set to enable run commands, when the operation mode changes the Inverter will
start running immediately. Take steps to ensure safety for such operation.
Introduction Chapter 1