XtraDrive User Manual Chapter 7: Using the Panel Operator
7-28
3. Press the MODE/SET key to display the encoder software version.
Software
Version
4. Press the DATA/SHIFT key for a minimum of one second to return
to the parameter code display.
7.2.8. Origin Search Mode
CAUTION
• Forward run prohibited (/P-OT) and reverse run prohibited (/N-OT) signals are not effective
during jog operations using parameter Fn003.
The Origin Search mode is designed to position the origin pulse
position of the encoder and to clamp at the position. This mode is used
when the motor shaft needs to be aligned to the machine. Execute the
origin search without connecting the couplings.
The speed for executing the origin search is 60rpm.
Mechanical origin
For aligning the motor
shaft with the machine.
The following conditions must be met to perform the origin search
operation.
• If the Servo-ON input signal (/S-ON) is ON, turn it OFF.
• Release the Servo-ON signal mask when the parameter Pn50A.1 is
set to 7, and the servo has been set to be always ON.