XtraDrive User Manual Chapter 7: Using the Panel Operator
7-37
3. Press the DATA/SHIFT key for a minimum of one second, and the
display will be as shown below.
4. Input the value (0001) and press the MODE/SET key. The display
will change as shown below and the write protection will be
established.
Flashing for
one second
5. Press the DATA/SHIFT key for a minimum of one second to return
to the Auxiliary Function mode display.
This completes the procedure for setting the write protection. The new
password setting will be valid after the next power OFF/ON cycle.
7.2.13. Clearing the Option Unit Detection Alarm
Alarm A.E7 (option unit detection failure) occurs the first time that the
XtraDrive servo amplifier is turned ON after disconnecting an option
board.
IMPORTANT
• Initialize the parameter settings with the servo OFF.
• After performing the procedure, cycle the power to reset all parameters to the default settings.
• Because the parameter has been set for the XtraDrive connected to an option board,
be sure to adjust the setting or initialize the parameter value (Fn005 of the Auxiliary Function
mode) to meet the current system needs.

Table of Contents

Other manuals for Omron XTRADRIVE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron XTRADRIVE and is the answer not in the manual?

Omron XTRADRIVE Specifications

General IconGeneral
BrandOmron
ModelXTRADRIVE
CategoryComputer Hardware
LanguageEnglish

Related product manuals