XtraDrive User Manual Chapter 5: Parameter Settings and Functions
5-69
The following parameter setting is used to change the CN1 connector
terminal that outputs the /S-RDY signal.
Parameter Signal Setting) Description
Pn50E Output Signal Selections 1 Default Setting: 3211 Position Control
The parameter is factory set so the /V-CMP signal is output between
CN1-29 and 30. See 5.3.4 Output Circuit Signal Allocation for more
details on parameter Pn50E.
5.5.7. Using the Warning Output Signal (/WARN)
This section describes the basic use and wiring procedure for the
warning (/WARN) output signal (photocoupler output signal).
The signal consists of the following two output signals.
Output Ö /WARN Warning Output Signal
Speed/Torque Control, Position
Control
This output signal indicates an overload or regenerative overload warning.
/WARN State
Status Result
ON Closed or low level. Error warning.
OFF Open or high level. Normal operation. No warning.
The following parameter setting is used to change the CN1 connector
terminal that outputs the /WARN signal.
Parameter Signal Setting Control Mode
Pn50F Output Signal Selections 2 Default Setting: 0000
Speed/Torque Control,
Position Control
Pn50F.3 is used to allocate the /WARN output signals above.
Output Terminal (CN1-)
Pn50F.3 State
*1 *2
0 — —
1 25 26
2 27 28
3 29 30

Table of Contents

Other manuals for Omron XTRADRIVE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron XTRADRIVE and is the answer not in the manual?

Omron XTRADRIVE Specifications

General IconGeneral
BrandOmron
ModelXTRADRIVE
CategoryComputer Hardware
LanguageEnglish

Related product manuals