EasyManuals Logo

Omron XTRADRIVE User Manual

Omron XTRADRIVE
333 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #323 background imageLoading...
Page #323 background image
XtraDrive User Manual Appendix D: List of Parameters
D-6
*
After changing this parameter, cycle the main circuit and control power supplies to enable the new
settings.
2
The multi-turn limit is valid only when parameter Pn002.2 Absolute Encoder Usage is set to "2". The value will
be processed in the range of "+32767 to -32768" for other settings even if the value is changed. There is no need to
change the multi-turn limit except for in special cases. Be careful not to change the setting unless necessary.
3
The setting of parameter Pn111 is valid only when parameter Pn110.1 is set to 0.
4
Normally set to "0". When using an external regenerative resistor, set the capacity (W) of the regenerative
resistor.
5
The upper limit is the maximum output capacity (W) of the servo amplifier.
Note* Refer to XtraWare User Manual

Table of Contents

Other manuals for Omron XTRADRIVE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron XTRADRIVE and is the answer not in the manual?

Omron XTRADRIVE Specifications

General IconGeneral
BrandOmron
ModelXTRADRIVE
CategoryComputer Hardware
LanguageEnglish

Related product manuals