rack configurations. The dashes within the rack configuration columns of the table,
represent empty rack units that are covered with solid one-unit fillers. The rack unit 42
is at the top of the Exalogic machine and the rack unit 1 is at the bottom.
See a summary of the hardware components for the different Exalogic machine
configurations in Hardware Components of Exalogic.
Note:
Do not alter the rack layout. Do not use the free space in the rack for anything
other than a rack upgrade kit.
Table 1-2 Layout for all Exalogic machine configurations
Rack Unit Full
Rack
Half
Rack
Quarter
Rack
Eighth
Rack
Front View Rear View
U29 to U42 X - - - Compute Node Compute Node
U27, U28 X X - - Compute Node Compute Node
U26 X - - - Vented one-unit
filler
NM2-GW InfiniBand
Switch / Gateway
U25 X X X X Vented one-unit
filler
Cisco Ethernet
Management Switch
U24 X - - - Vented one-unit
filler
NM2-GW InfiniBand
Switch / Gateway
U23 X X X X Vented one-unit
filler
NM2-GW InfiniBand
Switch / Gateway
U21, U22 X X X X Storage Appliance
Server Head
Storage Appliance
Server Head
U17 to U20 X X X X Storage Appliance
Disk Shelf
Storage Appliance
Disk Shelf
U16 X X X X Vented one-unit
filler
NM2-GW InfiniBand
Switch / Gateway
U10 to U15 X X - - Compute Node Compute Node
U06 to U09 X X X - Compute Node Compute Node
U02 to U05 X X X X Compute Node Compute Node
U01 X X - - Vented one-unit
filler
NM2-36P InfiniBand
Switch
1.4 Operational Procedures for Exalogic Machines
This section includes the following topics:
• Non-emergency Power Procedure
• Emergency Power-off Considerations
Operational Procedures for Exalogic Machines
1-4 Oracle Exalogic Elastic Cloud Machine Owner's Guide