fails, all resources (except the one that is locked to the active node) will be taken over
by the passive storage head.
In the example configuration for an active head, igb0 is used as the administrative
network interface for the active storage head, such as storagenode1. The lock
symbol indicates that igb0 is locked to this storage head. To access this active storage
head in a browser, you can use the following URL using either the host name or the IP
address:
https://storagenode1:215
or
https://<IP_storagenode1>:215
In the example configuration for a passive head, igb1 is used as the administrative
network interface for the passive storage head, such as storagenode2. The lock
symbol indicates that igb1 is locked to this storage head. To access this passive
storage head in a browser, you can use the following URL using either the host name
or the IP address:
https://storagenode2:215
or
https://<IP_storagenode2>:215
Note:
For more information about network configuration for the storage appliance,
see the Network topic in the Oracle ZFS Storage Appliance Administration Guide.
8.4.4 Network Configuration Options
You can choose any of the following network configuration options for the storage
appliance, based on your specific requirements:
• Configure Option 1: ASR Support and Separate Paths for Management and
Disaster Recovery
• Configure Option 2: ASR Support and Shared Path for Management and Disaster
Recovery, with Single Management URL
• Configure Option 3: ASR Support and No Disaster Recovery, But with Single
Management URL
8.4.4.1 Configure Option 1: ASR Support and Separate Paths for Management and
Disaster Recovery
In this default configuration, the igb0 port on your active storage head (head 1) is
used, and the management option is enabled. The igb0 port on your stand-by storage
head (head 2) is not used. The igb1 port on your stand-by storage head (head 2) is
used, and the management option is disabled. The igb2 and igb3 ports are bonded
with IP Multipathing (IPMP), and the management option is disabled on both igb2
and igb3.
Tip:
Administrators should remember to use two different management URLs for
the storage heads.
Configuration Overview
Configure the Storage Appliance 8-7