Automatic Operation (Synchronous Control)
8-20
Editing of the cam table
Edit the cam table data that was created.
Set the following items for each section set:
Starting phase (%)
Displacement (%)
Cam curve
The cam curve changes according to the settings.
KEY POINTS
The termination phase cannot be set. The termination phase will be
changed automatically if the staring phase is changed.
Do not make a radical displacement change of set cam curves. There is a
possibility that the motor cannot keep up with the output in the case of
rapid displacement.
Similarly, make settings that a phase of 0% and that of 100% are the same in
displacement.