15.3 Error Code Table
15-13
Error
code
Error name Description Object Recovered Countermeasures
4600H Pulse input setting error
The pulse input settings are
incorrect.
Each
axis
Yes
Check the set value.
Check the combination
of the input type, input
multiplication, and input
application.
4605H
Pulse count value
change setting error
The set pulse count change
value is out of the range.
Each
axis
Yes
Check the set value.
4609H
Automatic movement
amount check method
setting error
The operation of the
automatic check function of
movement amount is
incorrect.
Each
axis
Yes
4610H
Automatic movement
amount correction
numerator setting error
The automatic movement
amount correction numerator
is out of the range.
Each
axis
Yes
4611H
Automatic movement
amount correction
denominator setting
error
The automatic movement
amount correction
denominator is out of the
range.
Each
axis
Yes
4613H
Automatic movement
amount check interval
setting error
The automatic movement
amount check interval is out
of the range.
Each
axis
Yes