Errors and Warnings
15-12
Error
code
Error name Description Object Recovered Countermeasures
4250H
Current value update
error
The set value of the current
value update is out of the
range.
Each
axis
Yes
Check the set value.
If an error occurs
repeatedly with the
correct set values,
consult your Panasonic
representative.
4301H
Absolute/incremental
setting error
A value other than the
absolute/increment is set for
the move method.
Each
axis
Yes
4302H Dwell time error
The set value of the dwell
time is out of the range.
Each
axis
Yes
4303H
Positioning starting
table No. error
The specified table number is
0, or it exceeds the maximum
table number.
Each
axis
Yes
4304H Table setting error
The last table of the
positioning setting tables is
not the E point.
Each
axis
Yes
4400H
Positioning movement
amount setting error
The movement amount of the
positioning operation is out of
the range.
Each
axis
Yes
4401H
Positioning
acceleration/deceleratio
n type error
The acceleration/
deceleration type of the
positioning operation is
incorrect.
Each
axis
Yes
4402H
Positioning acceleration
time error
The acceleration time of the
positioning operation is out of
the range.
Each
axis
Yes
4403H
Positioning deceleration
time error
The deceleration time of the
positioning operation is out of
the range.
Each
axis
Yes
4404H
Positioning target speed
error
The target speed of the
positioning operation is out of
the range.
Each
axis
Yes
4500H Interpolation type error
The setting of the
interpolation type is incorrect.
Each
axis
Yes
4504H
Circular interpolation
not executable
The parameter of the circular
interpolation (such as center
point or pass point) is
incorrect.
Each
axis
Yes
4505H
Spiral interpolation not
executable
The error occurred while the
positioning unit is in spiral
interpolation operation as the
set value is incorrect.
Each
axis
Yes