17.6 Details of Each Axis Setting Area in Unit Memory
17-47
Offset
address
Name Default Setting range and description
03BH
Pulser operation
method
0
Area to set the single and interpolation operation pattern of positioning.
0: Standard operation
1: Speed limit (pulse hold)
2: Speed limit (truncated)
Any other settings will be errors.
03CH
− − −
03DH
− − −
03EH
− − −
03FH
− − −
040H
− − −
041H J-point control code 0H
Set the control code for J-point control.
bit Name Default Description
0
1 Acceleration/
Deceleration pattern
settings
0
0: Linear
acceleration/deceleration
1: S-shaped
acceleration/deceleration
2 to 15
042H
J-point acceleration
time
100
Sets the acceleration/deceleration time for J-point control.
Setting range: 0 to 10,000 (ms)
Any other settings will be errors.
043H
J-point deceleration
time
044H
J-point target speed 1,000
Sets the target speed for J-point control.
Setting range: 0 to 32,767,000
Any other settings will be errors.
Set the following range according to the unit setting.
Pulse: 1 to 32,767,000 pps
μm: 1 to 32,767,000 μm/s
inch: 0.001 to 32,767.000 inch/s
degree: 0.001 to 32,767.000 rev/s
045H
046H
− − −
047H
− − −
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com