11
9928491 R04 - 2017-2018 RZR XP Turbo / XP4 Turbo Service Manual
© Copyright Polaris Industries Inc.
11.41
WARNING
An overheated battery could explode, causing severe
injury or death. Always watch charging times carefully.
Stop charging if the battery becomes very warm to the
touch. Allow it to cool before resuming charging.
STATE OF
CHARGE
VOLTAGE
(DC)
ACTION
CHARG-
E TIME
100%
12.8 or
more
None, check
again in 3
months
None
Required
75% -
100%
12.6 - 12.8
May need
slight charge
3 - 6 hrs
50% - 75% 12.3 - 12.6
Needs
Charge
5 - 11 hrs
25% - 50% 12.0 - 12.3
Needs
Charge
At least
13 hrs
0% - 25% 12.0 or less
Needs
Charge
At least
20 hrs
NOTE
Follow the charger instructions supplied by the
manufacture regarding the order or connections, switch
positions and when to connect the charger to an outlet.