Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DS-562I RFL Electronics Inc.
June 14, 2007 5 (973)
334-3100
4. Once the Adapter Module has been selected, set it for the following desired configuration as
applicable:
MA-406IA
Select DCE or DTE mode by installing J2 jumpers
MA-406IB
Select DCE or DTE mode by installing J2 jumpers
MA-407I
No configuration is required for this module.
MA-408I
No configuration is required for this module.
MA-409IA
Select DCE or DTE:
DCE: Set jumpers J1 to J9 to DCE
DTE: Set jumpers J1 to J9 to DTE
MA-410I
DCE: S1-1 to S1-4 (toward “DCE”)
DTE: S1-1 to S1-4 (toward “DTE”)
MA-600
No configuration is required for this module.
MA-620
Select Normal or Inverted Data:
Norm
al Data: SW1-1 (DOWN)
Inverted Data: SW1-1 (UP)
5. Insert the Adapter Module into the rear of the shelf directly behind the module slot where the DS-562I
will be installed. Secure the module with the two screws provided.
6. Connect the Adapter Module to the user equipment using the connector pin assignments detailed in
Tables 1, 2, 3, 4, 5, or 6 as applicable.
7. Refer to Figure 7 for the location of switches on the DS-562I
8. On the DS-562I check the setting of toggle switch SW6.
SW6 controls the loopback, up to enable equipment loopback, down to enable
payload loopback, or center for no loopback. Set SW6 to the center position.
9. On the DS-562I check the setting of DIP switch SW7-1 through SW7-6.
SW7-1 through SW7-6 controls the modules SCB address. Set the switches to achieve the
desired SCB address setting as shown in Table 7.
10. On the DS-562I check the setting of DIP switch SW7-7.
SW7-7 turns the DS-562I’s service on or off. Down turns the service off (board disabled) up
turns the service on (board enabled). Set the switch down.
11. On the DS-562I check the setting of DIP switch SW7-8.
SW7-8 sets the DS-562I for local or remote control. Down places the DS-562I in
remote mode (settings obtained from the SCB), up sets the module for local
mode (settings obtained from the DIP switches). Set the switch up.