Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DS-562I RFL Electronics Inc.
June 14, 2007 7 (973)
334-3100
22. On the DS-562I check the setting of DIP switch SW5-2.
SW5-2 turns the handshaking delay on or off. Right sets no delay, left sets an 8
microsecond delay.
23. On the DS-562I check the setting of DIP switch SW5-3.
SW5-3 selects normal or inverted data. Right sets normal data, left sets inverted
data, this setting inverts incoming and outgoing data from the interface.
24. Install the DS-562I into the IMUX 2000 chassis and allow a few seconds for the board to
complete its power-up process.
25. Turn the DS-562I’s service to ON (SW7-7). Allow a minimum of 16 seconds to ensure the
common module has read all configuration data from the module.
26. Verify performance of the module using loopback testing.
27. When the configuration and performance of the DS-562I has been verified, set the module to
remote mode (SW7-8).