Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.
RFL DS-562NC RFL Electronics Inc.
July 5, 2012 44 (973)
334-3100
IMUX 2000 DS-562NC AND RFL 9745 (RS-449, RS-530)
Interfacing an IMUX 2000 DS-562NC with an RFL 9745 can be accomplished as follows:
A. The programmable jumpers on the 9745 RS-449 I/O shall be positioned as follows:
J1 (Send Timing): “Invert” Position
J2 (Receive Timing): “Invert” Position
B. The configuration of the IMUX 2000 RS-449 Channel Card shall be as follows:
1. DS-562NC with MA-406IA I/O
MA-406IA I/O: J2 jumpers in DCE mode
J3 in any position
DS-562NC, Switch SW6-5 (Receive Clock Polarity): Normal - OFF (DOWN)
DS-562NC, Switch SW6-7 (Transmit Clock Polarity): Normal - OFF (DOWN)
2. DS-562NC with MA-600 short haul fiber I/O
MA-600 I/O: No jumpers to set
DS-562NC, Switch SW6-5 (Receive Clock Polarity): Normal - OFF (DOWN)
DS-562NC, Switch SW6-7 (Transmit Clock Polarity): Normal - OFF (DOWN)
C. Confirm Clock and Data Transitions to Insure Proper System Operation as follows:
1. RFL 9745 RS-449 I/O: The positive edge of the RxClock (TP4 or RT) must be in the center of
the RxData bit (TP2 or RD).
2. IMUX 2000: DS-562NC - The positive edge of the TxClock (TP16) must be in the
center of the TxData bit (TP15).