Table 32. Remote status messages (“S” codes) Continued……
S Code Bits Used Value Description
1 0 0 0 0 1 56Kbps B 0 0 0 0 0 0 0 0
↑ ↑ ↑ ↑ ↑ ↑
0 0 0 0 0 1 64Kbps (N = 1)
0 x x x x x Valid N x 64 Baud Rate Settings where N = (1 to 31)
0 1 1 1 1 1 1984Kbps (N = 31)
0 Baud Rate Setting Invalid
S04
(Baud Rate Status)
B 0 0 0 0 0 0 0 0
↑
1 Baud Rate Setting valid
0 Transmit clock OK or not available for Head B 0 0 0 0 0 0 0 0
↑
1 Transmit clock slip occurred
0 Receive clock OK or not available for Head B 0 0 0 0 0 0 0 0
↑
1 Receive clock slip occurred
0 Phase Locked Loop for Bus ‘B’ not OK B 0 0 0 0 0 0 0 0
↑
1 Phase Locked Loop for Bus ‘B’ OK
0 Phase Locked Loop for Bus ‘A’ not OK B 0 0 0 0 0 0 0 0
↑
1 Phase Locked Loop for Bus ‘A’ OK
0 Bus ‘A’ and ‘B’ are not locked B 0 0 0 0 0 0 0 0
↑
1 Bus ‘A’ and ‘B’ locked
0 Bus ‘B’ not OK B 0 0 0 0 0 0 0 0
↑
1 Bus ‘B’ OK
0 Bus ‘A’ not OK
S05
(PLL/Bus/Clock
Status)
B 0 0 0 0 0 0 0 0
↑
1 Bus ‘A’ OK
S06 B 0 0 0 0 0 0 0 0
_ _ _ _ _ _ _ _
Not defined (Reserved for future use)
S07 B 0 0 0 0 0 0 0 0
_ _ _ _ _ _ _ _
Not defined (Reserved for future use)
S08 B 0 0 0 0 0 0 0 0
_ _ _ _ _ _ _ _
Not defined (Reserved for future use)
S09 B 0 0 0 0 0 0 0 0
↑ ↑ ↑ ↑ ↑
ECB Revision Number
(N = 1 to 31)
S010 B 0 0 0 0 0 0 0 0
↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑
Actel Revision Number