Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DS-562NC RFL Electronics Inc.
July 5, 2012 55 (973)
334-3100
Table 32. Remote status messages (“S” codes) Continued……
S Code Bits Used Value Description
0 T1/E1 Transmit Data not Active B 0 0 0 0 0 0 0 0
1 T1
/E1 Transmit Data Active
0 T1/E1 Receive Data not Active B 0 0 0 0 0 0 0 0
1 T1/E1 Receive Data Active
0 T1/E1 Transmit Addressing Not Enabled (56K Only) B 0 0 0 0 0 0 0 0
1 T1/E
1 Transmit Addressing Enabled (56K Only)
B 0 0 0 0 0 0 0 0
Bit4
0
T1/E1 Receive Addressing Not Enabled (56K Only)
B 0 0 0 0 0 0 0 0
Bit4 Bit3
1 0
T1/E1 Receive Addressing Fail (56K Only)
B 0 0 0 0 0 0 0 0
Bit4 Bit3
1 1
T1/E1 Receive Addressing OK (56K Only)
0 T1 MUXB 0 0 0 0 0 0 0 0
1 E1 MUX
0 Configuration InvalidB 0 0 0 0 0 0 0 0
1 Configuration Valid
0 Module Service OFF (Qualified)
1
S02
(Module Status)
B 0 0 0 0 0 0 0 0
1 Module Service ON (Qualified)
2
0 The payload loopback is disabled B 0 0 0 0 0 0 0 0
1 The payl
oad loopback is enabled
0 The equipment loopback is disabled B 0 0 0 0 0 0 0 0
1 The equipment loopback is enabled
B 0 0 0 0 0 0 0 0
Bit3
0
Octet Timing disabled or not used
B 0 0 0 0 0 0 0 0
Bit3 Bit2
1 0
Octet Timing not detected (G.703 only)
B 0 0 0 0 0 0 0 0
Bit3 Bit2
1 1
Octet Timing detected (G.703 only)
S03
(Interface Status)
B 0 0 0 0 0 0 0 0
Not used
1
Either the Service is OFF or has configuration errors.
2
The service is ON and has no configuration errors.