Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL OCUDP RFL Electronics Inc.
July 15, 2010 20 (973)
334-3100
Table 6. – continued, Remote status messages (“S” codes) for OCUDP module
S CODE Position Value Description
S2 B 0 0 0 0 0 0 0 0
- - - -
LOOP LENGTH
See Table 7
B 0 0 0 0 0 0 0 0
- - - - - - -
RECEIVER CONVERGING
1 Receiver converging process (condition exists during
link synchronization)
0 Synchronization complete or failed
B 0 0 0 0 0 0 0 0
- - - - - - -
FULL OPERATION
1 Full operation of metallic line receiver
0 metallic line receiver operation impaired
B 0 0 0 0 0 0 0 0
- - - - - - -
LEVEL DETECTION
1 Level detection
0 NO level detection
B 0 0 0 0 0 0 0 0
- - - - - - -
RECEIVE LOSS OF
SIGNAL
1 Receive loss of signal
0 NO receive loss of signal
S3
B 0 0 0 0 0 0 0 0
RX SIGNAL MAGNITUDE
00000000 to
11111111
See LEVEL ONE LXT400 data sheet