Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
Table 4. TX Level Settings Table 5. RX Level Settings
Nominal Level at
Line
TX
Switch
Setting*
Digital
(T1)
Digital
(T1)
RX
Sw
itch
Setting*
Nominal Level at
Line
Vrms dBm dBm dBm
2.449 +10 +10 0
2.183 +9 +9 0
1.946 +8 +8 0
1.734 +7 +7 0
1.546 +6 +6 0
1.377 +5 +5 0
1.228 +4 +4 0
1.094 +3 +3 0
0.975 +2 +2 0
0.869 +1 +1 0
0.775 +0 +0 0
0.690 -1 -1 0
0.615 -2 -2 0
0.548 -3 -3 0
0.489 -4 -4 0
0.436 -5 -5 0
0.388 -6 -6 0
0.346 -7 -7 0
0.308 -8 -8 0
0.275 -9 -9 0
0.245 -10 -10 0
0.218 -11 -11 0
0.195 -12 -12 0
0.173 -13 -13 0
0.155 -14 -14 0
0.138 -15 -15 0
0.123 -16 -16 0
0.109 -17 -17 0
0.098 -18 -18 0
0.087 -19 -19 0
0.077 -20 -20 0
0.069 -21 -21 0
0.062 -22 -22 0
0.055 -23 -23 0
dBm dBm dBm Vrms
0 +10 +10 2.449
0 +9 +9 2.183
0 +8 +8 1.946
0 +7 +7 1.734
0 +6 +6 1.546
0 +5 +5 1.377
0 +4 +4 1.228
0 +3 +3 1.094
0 +2 +2 0.975
0 +1 +1 0.869
0 +0 +0 0.775
0 -1 -1 0.690
0 -2 -2 0.615
0 -3 -3 0.548
0 -4 -4 0.489
0 -5 -5 0.436
0 -6 -6 0.388
0 -7 -7 0.346
0 -8 -8 0.308
0 -9 -9 0.275
0 -10 -10 0.245
0 -11 -11 0.218
0 -12 -12 0.195
0 -13 -13 0.173
0 -14 -14 0.155
0 -15 -15 0.138
0 -16 -16 0.123
0 -17 -17 0.109
0 -18 -18 0.098
0 -19 -19 0.087
0 -20 -20 0.077
0 -21 -21 0.069
0 -22 -22 0.062
0 -23 -23 0.055
0 -24 -24 0.049
0 -25 -25 0.044
0 -26 -26 0.039
0 -27 -27 0.035
0 -28 -28 0.031
0 -29 -29 0.027
0 -30 -30 0.024
0 -31 -31 0.022
0 -31.5 -31.5 0.021
(1)
(2)
(1)
(2)
*Use SW4-2 to SW4-7 for CH1 Tx setting
Use SW8-2 to SW8-7 for CH2 Tx setting
*Use SW5-2 to SW5-7 for CH1 Rx setting
Use SW9-2 to SW9-7 for CH2 Rx setting
Notes:
1. Settings shown on these lines are for 0dBm in and 0dBm out.
2. Settings shown on these lines are for -16dBm in and +7dBm out (factory default)
3. Setting the switches for levels outside the range of these tables will cause signal degradation.
RFL VF-5C RFL Electronics Inc.