“S” CODES
“S” codes appear in response to a “STATUS?” query. There are six “S” codes for the RFL VF-5C. Like
the “P” code, this number is displayed in both decimal and binary form. The seven most significant
digits of the binary number represent the conditions shown in Table 7. The least significant digit is not
used.
A typical response to a “STATUS?” query looks like this:
* OK
CHANNEL CARD 3, TYPE 78 (or 69)
S01 = 2 (B00000010)
S02 = 2 (B00000010)
S03 = 8 (B00001000)
S04 = 1 (B00000001)
S05 = 0 (B00000000)
S06 = 1 (B00000001);
Table 7. Remote status messages (“S” codes)
S Code Digit(s) And Switch Equivalent Value
(1)
Description
S1
B 0 0 0 0 0 0 0 0
- - - - - - -
0 Ch1 Config Valid
CH1 CONFIG INVALID
1 Ch1 Config Invalid
B 0 0 0 0 0 0 0 0
- - - - - - -
0 Ch1 Disabled
CH1 ENABLED
1 Ch1 Enabled
B 0 0 0 0 0 0 0 0
- - - - - - -
0 Ch1 E Lead Inactive
CH1 E LEAD
1 Ch1 E Lead Active
B 0 0 0 0 0 0 0 0
- - - - - - -
0 Ch1 M Lead Inactive
CH1 M LEAD
1 Ch1 M Lead Active
B 0 0 0 0 0 0 0 0
- - - - - - -
0 Ch1 2713 Loopback Inactive
CH1 2713 LOOPBACK
1 Ch1 2713 Loopback Active
B 0 0 0 0 0 0 0 0
- - - - - - -
0 C
h1 Address Mis-match
CH1 ADDRESS MATCH
1 Ch1 Address Match
B 0 0 0 0 0 0 0 0
- - - - - - - -
0 C
h1 Addressing Disabled
CH1 ADDRESSING
1 Ch1 Addressing Enabled
B 0 0 0 0 0 0 0 0
- - - - - - -
Will always read zero.
UNUSED BIT
>> table continues on next page <<