EasyManua.ls Logo

RFL Electronics IMUX 2000 - Page 705

Default Icon
982 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DS-TT RFL Electronics Inc.
January 31, 2008 3 (973)
334-3100
SPECIFICATIONS
As of the date this Instruction Data Sheet was published, the following specifications apply to the RFL
DS-TT module. Because all RFL products undergo constant refinement and improvement, these
specifications are subject to change without notice.
ENVIRONMENTAL
ANSI C37.90 - 1989 (service conditions)
Operating temperature - 20
o
C to + 55
o
C
Storage temperature - 40
o
C to + 75
o
C
Humidity 95% @ 40
o
C non-condensing
SWC/ FAST TRANSIENT
ANSI C37.90 - 1989 (dielectric)
ANSI C37.90.1 - 1989 (SWC & fast transient)
RFI SUSCEPTIBILITY
ANSI C37.90.2 35 V/M
OPTICAL INPUT SPECIFICATIONS
Operating voltage range:
48 Vdc 38-60 Vdc
125 Vdc 88-150 Vdc
250 Vdc 200-280 Vdc
Input threshold 1/2 nominal station battery
SOLID STATE OUTPUT SPECIFICATIONS
Maximum continuous output current 1 Amp
Maximum surge current (100 ms) 10 Amps
Minimum output current 20 ma
Maximum open circuit voltage 280 Vdc
OPTIONAL RELAY OUTPUTS
Maximum continuous current 2 A (inductive)
Maximum surge current (100 ms) 30 A
Maximum breaking current 1 A resistive
Maximum open circuit voltage 280 Vdc
Maximum operate time 5 ms

Table of Contents